TY - SER AU - Listewnik,Paulina AU - Ronowska,Monika AU - Wąsowicz,Michał AU - Tuchin,Valery V. AU - Szczerska,Małgorzata TI - Porous phantoms mimicking tissues - investigation of optical parameters stability over time KW - абсорбция KW - коэффициент стабильности KW - оптические параметры KW - оптические фантомы KW - статьи в журналах N1 - Библиогр.: 34 назв N2 - Optical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods, while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom in optical system. Measurements were performed in multiple series with an interval of 6 months, recreating the same conditions and using the same measuring system consisting of an integrating sphere, a coherent light source with a wavelength of 635 nm and a detector. Scattering and absorption parameters were determined on the basis of the measured reflectance and transmittance. The tested samples were made of silicone and glycerol in various proportions UR - http://vital.lib.tsu.ru/vital/access/manager/Repository/koha:000897641 ER -